Smoke Exhaust Fan Control Panel
9 the car park main smoke control panel at the fcc guard house and remote local panel for the supply and.
Smoke exhaust fan control panel. The fire and smoke control panel. Zoned smoke exhaust at 6 air changes per hour option permits reduction in volume of smoke exhaust in atrium parking garage vestibule ventilation 3 3 5 7 4 naturally with vent to the outdoors with min area of 0 4m2 or mechanically with 14m3 h flow for each m2 of vestibule floor area smoke protected seating areas 3 3 2 4 14. A key component in any smoke control system is the firefighter s smoke control panel. Typical smoke control systems will employ large exhaust fans and or air handling units.
This system is typically a ul864 uukl listed fire alarm system fas or ul864 uukl listed building automation system bas. Smoke control systems or smoke management systems are mechanical systems that control the movement of smoke during a fire. Equipment status indicators at panel iii. Other air sources may.
Consistent labeling between fans stairs panel 3. Smoke control activates via initiating devices smoke detector waterflow pull station 2. Fan intake clearance 2. Generally seen in larger complexes such as shopping centres these systems automatically exhaust any smoke from a fire affected area to prevent occupants being inundated by smoke.
While the fire alarm system postures the smoke control system immediately upon activation of a fire. The smoke control panel is intended to be installed in conjunction with an engineered smoke control system. 8 the smoke control sub panel in each smoke control zone is to be connected to the main smoke control panel such that any isolation of jet fan system at a particular zone is automatically displayed at the main smoke control panel. The most common systems referenced in current codes are atrium smoke exhaust systems and stair pressurization systems.
Jet fans smoke control systems are suitable for installation in large uncluttered spaces such as car parks and tunnels. Manual control at panel 4. Once proper system status is provided at the firefighter s smoke control panel the belts of a fan are. Fire fan control panels are used in conjunction with mechanical services air handling system and are primarily used for automatic smoke extraction during a fire event.
Jet fans smoke control system. Installing this type of fan eliminates the need to install costly ugly air inlet and extraction ducts improving visibility in car parks and increasing the available clearance gauge. This panel serves as a master station that a firefighter can monitor damper and fan status manually control fans or override automatically controlled fans. It is common to exhaust the fire floor pressurize the floor above and below and all of the vertical shafts.